CS-105 - Train Control Systems Documentation
페이지 정보

본문
The Track LED is on System is receiving incoming energy; Continue to the subsequent steps. 1. Go through the steps above for the problem: the UWT throttle says "LCC Server not found". Locomotives are automatically added to the operative memory when they are selected by a throttle. The CS-105 maintains an inner operative memory in regards to the locomotives that it's controlling. The CS-105 translates the pace steps of the selected DCC or M/M protocol to the scale pace of 0 to 126 mph reported to the LCC throttles. The suggestion is that for pace matching purposes the locomotive decoders needs to be configured with a velocity table that defines 1 (of 126) velocity steps as 1 scale mph; for example, calibrate the locomotive to run with 32 scale mph at velocity step 32, with 50 scale mph at speed step 50, etc. This makes the throttle display a speedometer, and any two locomotives could be consisted collectively. That is accomplished by sending the throttle an LCC message, which it shall automatically or manually reply to, indicating that it's alive and intending to regulate that locomotive.
You will notice a message when making an attempt to read or program a CV indicating that there was no RailCom suggestions. For extra technical data on how Direct mode programming works, see NMRA customary S-9.2.3. See the CS-105 WiFi Configuration section. The CS-105 is in WiFi Client mode, however not connected to your WiFi community. The loop makes the network inoperational. This occurs when the CS-105 is connected to JMRI through each WiFi and the LCC CAN-bus cable, and a loop is created in the LCC community. Remove either the WiFi or the wired connection between JMRI and the CS-105. The number of currently operating RailCom-enabled locomotives will be seen in the CS-105’s "Status"Status display screen by way of a TCS UWT or connected JMRI configuration window. For instance, handle 10L can be entered as "010" in the select loco screen. When one throttle modifications the consist velocity or capabilities, other throttles will mechanically update their screen. When a throttle releases a prepare, the heartbeat checking additionally stops.
Simply use your TCS throttle menu and select "Program Track" from the CV Programming menu. To make use of the programming monitor, open the menu in your UWT and navigate to option "four CV Programming" adopted by "2 Programming Track". If you don't place a locomotive on the programming track, or there is a few situation in communicating with the decoder on the programming observe, an error message will show stating that the loco/decoder was not detected. The system will then ask you to place a locomotive on the programming observe. It can be crucial to notice that no changes to the WiFi configuration will happen until the system is power cycled. The WiFi Full LED is on. Full Instructions with footage on learn how to update your CS-105 through TCS DEPOT might be found on the TCS Website. Macros and Macro Configuration are described in detail in supplementary documentation which might be found on the TCS webpage. This feature can be used to conveniently test or set the DCC Address of a decoder. To start programming an address, enter the Menu on the TCS throttle, select "4 CV Programming" after which select "3 DCC Address" from the list of choices as proven below.
Current Address, together with an indication for brief/Long format. Each locomotive, together with each consist member of a stored consist, occupies one entry in the "stack" of the CS-105. Similarly, the decoder also can send knowledge to the command station, together with CV values, that means that you will be able to read the CV values. Note that the maximum worth is 127. CV 19 consists use Bit 7 of the CV to pick out the path, cv power cable which means you've 127 ahead and 127 reverse values. The 2-digit "Short" tackle is saved in CV 1 and has a valid range of values from 1 to 127. A value larger than 127 is invalid for short addressing. Note: It is possible to set an extended address which falls within the brief handle range (1-127). If you need to pick out a protracted deal with inside the quick address range, you must add an extra "0" before the remainder of the handle when getting into it into the throttle. Because of this, it is strongly recommended to set your WiFi router to at all times assign a hard and fast (static) IP tackle to the command station.
- 이전글What Could GSA SER Verified Lists Do To Make You Swap? 24.12.26
- 다음글The Ultimate Hot Hot Fruit Guide: How to Play, Score Big, and Boost Your Jackpot Potential 24.12.26
댓글목록
등록된 댓글이 없습니다.